Power Source |
120 V AC, 60 Hz |
Rated Output |
1W |
Power Consumption |
317 W (rated output), 62 W (based on UL62368) 200 mA or less (when power switch is OFF) |
|
|
|
Frequency Response |
50 Hz to 20 kHz ±3 dB (1/8 rated output) |
Total Harmonic Distortion |
1 % or less at 1 kHz, rated power (20 kHz LPF (AUX-0025)) |
Tone Control |
Bass: ±10 dB at 100 Hz, Treble: ±10 dB at 10 kHz |
Signal to Noise Ration |
88 dB or more (Master volume: min) 76 dB or more (Master volume: max) 55 dB or more (INPUT 1 to 6) (A-weighted) |
Input |
1-2: |
-60 dB* (MIC)/-20 dB* (LINE) selectable, 600 Ω, electronically-balanced, removable terminal block (3.81 mm, 3 pins) Note: MIC inputs are equipped with phantom power (24 V DC, ON/OFF switchable). |
3-4: |
-60 dB*, 600 Ω, electronically-balanced, removable terminal block (3.81 mm, 3 pins) Note: Equipped with phantom power (24 V DC, ON/OFF switchable). |
5-6: |
MIC/LINE selectable MIC: -60 dB* , 600 Ω, electronically-balanced, removable terminal block (3.81 mm, 3 pins) LINE: -20 dB*, 10 kΩ, unbalanced, RCA pin jack x 2 |
|
|
Module 1-2 |
-20 dB*, 10 kΩ |
Output
|
Speaker |
High impedance: 70 V line/21 Ω/Low impedance 4 to 16 Ω Low impedance 4 to 16 Ω selectable |
REC: |
0 dB *, 600 Ω, unbalanced, RCA pin jack x 2 |
PRE AMP: |
0 dB *, 600 Ω, unbalanced, RCA pin jack |
Control Input |
4 channels, no-voltage make contact input, open voltage: 35 V DC or less, Short-circuit current: 10 mA or less, removable terminal block (3.81 mm, 4 pins) |
REMOTE VOLUME: No-voltage make contact input, open voltage: 35 V DC or less, Short circuit current: 10 mA or less, removable terminal block (3.81 mm, 4 pins) |
Control Output |
POWER REMOTE: Open collector output, withstand voltage: 30 V DC or less, control current: 25 mA or less, removable terminal block (3.50 mm, 4 pins) |
EMERGENCY OUT: Open collector output, withstand voltage: 30 V DC or less, control current: 25 mA or less, removable terminal block (3.50 mm, 4 pins) |
Indicators |
LED level meter, Power indicator, Network connection confirmation indicator, Priority broadcast indicator, Emergency broadcast indicator, Thermal protection indicator, Over-current protection indicator, CPU running indicator, Error indi-cator |
Operating Temperature |
-10 to +40 ˚C (14 to 104 ˚F) |
Operating Humidity |
85 % RH or less (no condensation) |
Finish |
Panel: ABS resign, black
Case: Surface-treated steel plate, black, paint |
|
|
Dimensions |
420 (w) x 96.1 (h) x 313.1 (d) mm or 16,54" x 3.78" x 12.33" |
Weight |
5.2 kg or 11.46 lb |
Options |
Input transformer: IT-450, Perforated panel: PF-013B |